The Walker A30070 comes equipped with a differential pressure (DP) gauge, auto drain, and a 1/2" pipe size inlet with a flow rate of 70 SCFM. With the included E30612 Grade XA filter, this unit removes 0.01 micron particles with a maximum oil carryover of 0.003 ppm. Complies with ISO 8573-1: 2010 (maximum particle size class and maximum oil content).
Introducing the Alpha, Walker Filtration’s latest range of market leading compressed air and gas filters. With enhanced housing features and a step change in element performance, the Alpha delivers a high quality filtration solution you can trust.
Offered in a range of 18 models with connection sizes ranging from 1/8” to 3”, the Alpha Series has been tested to provide a saturated differential pressure of <1.8 psi (125 mbar) across X1 and XA grades—proving to be our most advanced filter to date.
With class leading performance and exceptional results in oil aerosol and particle retention, Alpha Compressed Air Filters deliver significantly reduced pressure loss and optimum filtration efficiencies—to ensure continually low operational costs.
Filter Model | Pipe Size inches |
Inlet Flow Rate* | Dimensions inches (mm) | Weight | ||||||
SCFM | Nm³/hr | A | B | C | D | lb | kg | |||
A30070 |
1/2 | 70 | 119 | 5.00 (127) | 1.26 (32) | 11.22 (285) | 3.15 (80) | 3.7 | 1.7 |
*Rated flow at 100 psi (7 bar), reference conditions at 14.5 psi (a) (1 bar (a)) 35ºF (20ºC)
Grade | X5 | X1 | XA | AC | ||||
Particle removal | 5 micron | 1 micron | 0.01 micron | 0.01 micron | ||||
Maximum particle size class** | 4 | 3 | 1 | 1 | ||||
Maximum oil content** | 4 | 3 | 1 | 1 | ||||
Maximum oil carryover at 68°F (20°C) | 5 ppm | 5 mg/m³ | 0.3 ppm | 0.3 mg/m³ | 0.01 ppm | 0.01 mg/m³ | 0.003 ppm | 0.003 mg/m³ |
Pressure loss - clean & dry | 0.6 psi | 40 mbar | 0.8 psi | 55 mbar | 1.2 psi | 85 mbar | 1.7 psi | 115 mbar |
Pressure loss - saturated | 1.1 psi | 75 mbar | 1.8 psi | 125 mbar | 1.8 psi | 125 mbar | N/A | N/A |
Pressure loss - element change | 12 months | 8000 hours | 8000 hours | 12 months | 8000 hours | 12 months | at least every 6 months | |
Maximum temperature - automatic drain | 176°F | 80°C | 176°F | 80°C | 176°F | 80°C | 122°F*** | 50°C*** |
Maximum working pressure - automatic drain | 232 psi | 16 bar | 232 psi | 16 bar | 232 psi | 16 bar | 232 psi | 16 bar |
Maximum temperature - manual drain | 248°F | 120°C | 248°F | 120°C | 248°F | 120°C | 122°F*** | 50°C*** |
Maximum working pressure - manual drain | 300 psi | 20.7 bar | 300 psi | 20.7 bar | 300 psi | 20.7 bar | 300 psi | 20.7 bar |
Element cap color |
Green | Red | Blue | Black |
** to ISO 8573-1: 2010
*** Maximum recommended operating temperature 77ºF (25ºC)
Pressure correction factors | For maximum flow rate, multiply model flow rate by the correction factor corresponding to the minimum operating pressure | |||||||||
Operating pressure psi (bar) | 58 (4) | 72 (5) | 87 (6) | 100 (7) | 115 (8) | 145 (10) | 174 (12) | 203 (14) | 232 (16) | 300 (20.7) |
100 psi - correction factor | 0.76 | 0.84 | 0.92 | 1.00 | 1.07 | 1.19 | 1.31 | 1.41 | 1.51 | 1.73 |
Nuvair offers parts and equipment manufactured by Walker Filtration. Some products may not be available for online purchase and others may have extended lead times. To confirm compatibility with your existing equipment or to ensure the product meets your needs, please contact the Nuvair Sales Team for ordering assistance by email or phone.