Nuvair manufacturers low pressure volume tanks (air receivers) in horizontal, vertical, grasshopper, and top plate configurations. Standard sizes from 13.3 to 400 gallon sizes with larger sizes available. Packages with breathing air filtration are built around high quality tanks to the latest ASME code. The volume tanks are painted with a primer coat and optional durable acrylic enamel top coat. Framed tanks are enclosed in rugged marine grade aluminum frames and have eyes and/or forklift feet. Brass fittings and stainless steel hardware are used on all our low volume tanks. Breathing air packages are available with Norgren or Hankison filter systems installed and additional types of inlet and outlet fittings.
The use of a volume tank with low pressure compressors has several purposes:
Removal of moisture
Decrease the wear and tear of your compressor by reducing cycling
Provide a short back up supply of air should the compressor be shut off
Nuvair stocks 15-, 30-, 60-, 80-, 120- and 200-gallon volume tanks and can custom order larger tanks.
Standard Features
Our standard framed tanks are made with 1-1/2" marine grade aluminum stock and can be built thicker
Inlet valves are 1/2" and 2" in brass ball valve with #10 JIC brass fitting and 1/2" brass check valve
Outlet manifolds from one to four standard 1/2" brass ball valves with #10 JIC brass fittings
Drain Valve 1/4" brass ball valve standard additional sizes custom
Pressure gauge 0 to 300 psi
ASME tanks have a pressure relief valve 1/4" set at 200 psi
Designed and constructed in accordance with ASME Section VIII Div-I Code for Compressed Air Storage Use
"U" stamped and registered with the National Board of Pressure Vessel Inspectors
Most designs include Canadian Registration Numbers (CRN)
Exterior surface painted with one coat standard shop primer
Options
Special exterior and interior coatings available upon request
Capable of building to American Bureau of Shipping (ABS) and United States Coast Guard (USCG) codes