Double Acting, Single Stage “AGD” boosters not only pump twice the volume of a Single Acting, Single Stage Booster per cycle, but also require less air drive since the inlet gas pressure is assisting the air drive in each direction, providing a substantial portion of the required driving force. These models provide efficient means of boosting large volumes of gas at low to medium compression ratios.
SKU | Maximum Rated Gas Supply |
Minimum Gas Supply Pressure |
Maximum Rated Gas Outlet: psi (bar) |
Static Stall Pressure |
Piston Displacement Per Cycle |
Gas Inlet/Outlet |
Weight | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | psi | bar | psi | bar | Inert Gas | Oxygen | Formula† | cu in | ML | Connections | lb (kg) |
AGD-4 | 1250 | 86 | ATM | ATM | 1250 (86) |
1250 (86) |
4 Pa+Ps | 19.3 | 316.3 | 3/8” NPT | 31 (14) |
AGD-7 | 2500 | 172 | 25 | 1.7 | 2500 (172) |
2500 (172) |
7 Pa+Ps | 26.4 | 432.6 | * | 35 (16) |
AGD-15-O2‡ | 5000 | 345 | 50 | 3.5 | 5000 (345) |
5000 (345) |
15 Pa+Ps | 12.4 | 203.2 | ** | 35 (16) |
AGD-30 | 9000 | 650 | 100 | 7 | 9000 (620) |
5000 (345) |
30 Pa+Ps | 6.2 | 101.6 | ** | 38 (17) |
AGD-30-O2‡ | 9000 | 650 | 100 | 7 | 9000 (620) |
5000 (345) |
30 Pa+Ps | 6.2 | 101.6 | ** | 38 (17) |
AGD-32 | 5000 | 345 | 50 | 3.5 | 5000 (345) |
5000 (345) |
30 Pa+Ps | 12.4 | 203.2 | ** | 49 (22) |
AGD-32-O2‡ | 5000 | 345 | 50 | 3.5 | 5000 (345) |
5000 (345) |
30 Pa+Ps | 12.4 | 20.32 | ** | 49 (22) |
AGD-62 | 5000 | 345 | 200 | 14 | 9000 (620) |
5000 (345) |
60 Pa+Ps | 6.2 | 101.6 | ** | 49 (22) |
Maximum outlet pressure is drive area ratio times air drive pressure PLUS gas supply pressure. Suggested cycling speed for maximum seal life: 60 CPM.
† Ps = Gas Supply Pressure, Pa = Drive Pressure, Po = Outlet Pressure
‡ The AGD-15-O2, AGD-30-O2, and AGD-32-O2 boosters are "oxygen service" ready equipment. Boosters are not oxygen service ready unless otherwise noted.
* Inlet Port: 3/8 in NPT. Outlet Port: 3/8 in NPT. 2 each: inlet & outlet.
**Interchangeable 3-3/8 in SAE or 1/4 in - H/P both ports. 2 each: inlet & outlet.
Please contact the sales team for estimated lead times.
Sample performance shown below is used for general reference only; consult Nuvair sales for specific performance information.
LEGEND
Pa = Air Drive Pressure
Ps = Gas Supply Pressure
Qa = Air Drive Quantity
Po = Gas Outlet Pressure
Q = Gas Outlet Flow Rate
SKU | PA = 90 psi | |||
---|---|---|---|---|
Model | Qa | Ps | Po | Q |
AGD-4 | 30 30 30 30 |
500 350 200 50 |
800 600 400 200 |
33 25.4 16 4.5 |
AGD-7 | 30 30 30 30 |
700 500 300 100 |
1300 1000 800 500 |
16 18.8 11.2 4 |
AGD-15-O2‡ | 40 40 40 40 |
2100 1500 900 300 |
3000 2400 1800 1200 |
50.3 36.1 21.5 6.7 |
AGD-30 | 40 40 40 40 |
2850 2250 1550 850 |
4200 4200 3200 2800 |
35.6 25.5 19 9.6 |
AGD-30-O2‡ | 40 40 40 40 |
2850 2250 1550 850 |
4200 |
35.6 25.5 19 9.6 |
AGD-32 | 50 40 28 33 |
2950 2250 1550 850 |
4400 4400 4000 3200 |
57.7 33.2 15.4 9.7 |
AGD-32-O2‡ | 50 40 28 33 |
2950 2250 1550 850 |
4400 4400 4000 3200 |
57.7 33.2 15.4 9.7 |
AGD-62 | 50 41 25 45 |
4000 3250 2500 1000 |
7500 7500 7500 5000 |
35.6 23.6 11 8 |
Nuvair offers authentic parts and equipment manufactured by Haskel® International, an Ingersoll Rand Business. Beware of inexpensive aftermarket imitations labeled as "replacement," "OEM equivalent," "compatible," or "alternative," as they are not made by Haskel International. Due to size, weight, or specific requirements, some Haskel products may not be available for online purchase, and others may have extended lead times. To confirm compatibility with your existing equipment or to ensure the product meets your needs, please contact the Nuvair Sales Team for ordering assistance by email or phone.