Double Acting, Single Stage “AGD” boosters not only pump twice the volume of a Single Acting, Single Stage Booster per cycle, but also require less air drive since the inlet gas pressure is assisting the air drive in each direction, providing a substantial portion of the required driving force. These models provide efficient means of boosting large volumes of gas at low to medium compression ratios.
SKU | Maximum Rated Gas Supply |
Minimum Gas Supply Pressure |
Maximum Rated Gas Outlet: psi (bar) |
Static Stall Pressure |
Piston Displacement Per Cycle |
Gas Inlet/Outlet |
Weight | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
Model | psi | bar | psi | bar | Inert Gas | Oxygen | Formula† | cu in | ML | Connections | lb (kg) |
AGD-4 | 1250 | 86 | ATM | ATM | 1250 (86) |
1250 (86) |
4 Pa+Ps | 19.3 | 316.3 | 3/8” NPT | 31 (14) |
AGD-7 | 2500 | 172 | 25 | 1.7 | 2500 (172) |
2500 (172) |
7 Pa+Ps | 26.4 | 432.6 | * | 35 (16) |
AGD-15-O2‡ | 5000 | 345 | 50 | 3.5 | 5000 (345) |
5000 (345) |
15 Pa+Ps | 12.4 | 203.2 | ** | 35 (16) |
AGD-30 | 9000 | 650 | 100 | 7 | 9000 (620) |
5000 (345) |
30 Pa+Ps | 6.2 | 101.6 | ** | 38 (17) |
AGD-30-O2‡ | 9000 | 650 | 100 | 7 | 9000 (620) |
5000 (345) |
30 Pa+Ps | 6.2 | 101.6 | ** | 38 (17) |
AGD-32 | 5000 | 345 | 50 | 3.5 | 5000 (345) |
5000 (345) |
30 Pa+Ps | 12.4 | 203.2 | ** | 49 (22) |
AGD-32-O2‡ | 5000 | 345 | 50 | 3.5 | 5000 (345) |
5000 (345) |
30 Pa+Ps | 12.4 | 20.32 | ** | 49 (22) |
AGD-62 | 5000 | 345 | 200 | 14 | 9000 (620) |
5000 (345) |
60 Pa+Ps | 6.2 | 101.6 | ** | 49 (22) |
Maximum outlet pressure is drive area ratio times air drive pressure PLUS gas supply pressure. Suggested cycling speed for maximum seal life: 60 CPM.
† Ps = Gas Supply Pressure, Pa = Drive Pressure, Po = Outlet Pressure
‡ The AGD-15-O2, AGD-30-O2, and AGD-32-O2 boosters are "oxygen service" ready equipment. Boosters are not oxygen service ready unless otherwise noted.
* Inlet Port: 3/8 in NPT. Outlet Port: 3/8 in NPT. 2 each: inlet & outlet.
**Interchangeable 3-3/8 in SAE or 1/4 in - H/P both ports. 2 each: inlet & outlet.
Please contact the sales team for estimated lead times.
Sample performance shown below is used for general reference only; consult Nuvair sales for specific performance information.
LEGEND
Pa = Air Drive Pressure
Ps = Gas Supply Pressure
Qa = Air Drive Quantity
Po = Gas Outlet Pressure
Q = Gas Outlet Flow Rate
SKU | PA = 90 psi | |||
---|---|---|---|---|
Model | Qa | Ps | Po | Q |
AGD-4 | 30 30 30 30 |
500 350 200 50 |
800 600 400 200 |
33 25.4 16 4.5 |
AGD-7 | 30 30 30 30 |
700 500 300 100 |
1300 1000 800 500 |
16 18.8 11.2 4 |
AGD-15-O2‡ | 40 40 40 40 |
2100 1500 900 300 |
3000 2400 1800 1200 |
50.3 36.1 21.5 6.7 |
AGD-30 | 40 40 40 40 |
2850 2250 1550 850 |
4200 4200 3200 2800 |
35.6 25.5 19 9.6 |
AGD-30-O2‡ | 40 40 40 40 |
2850 2250 1550 850 |
4200 |
35.6 25.5 19 9.6 |
AGD-32 | 50 40 28 33 |
2950 2250 1550 850 |
4400 4400 4000 3200 |
57.7 33.2 15.4 9.7 |
AGD-32-O2‡ | 50 40 28 33 |
2950 2250 1550 850 |
4400 4400 4000 3200 |
57.7 33.2 15.4 9.7 |
AGD-62 | 50 41 25 45 |
4000 3250 2500 1000 |
7500 7500 7500 5000 |
35.6 23.6 11 8 |