Oxygen Compatible Air (OCA) filter element contains molecular sieve, silica gel, high filtration carbon, and CO catalyst in a disposable cartridge filter. Removes moisture, hydrocarbons, carbon monoxide, carbon dioxide, oil, taste/odor, and particles. Designed for Lawrence-Factor HF.
Typical Application | Hyper Hydrocarbons |
---|---|
Removes | H2O, CO, CO2, hydrocarbons, oil, taste, odor, and particles |
Dimensions | 2.75" OD x 27" L |
Contents | Molecular sieve, high filtration carbon, CO catalyst, silica gel |
Micron Rating | 2μ particles |
DO NOT drop filter into housing. |
REPLACE FILTERS AS A SET. |
DO NOT use where operating temperature could exceed 120°F (49ºC). Use of a temperature alarm is recommended. |
HEAT & HUMIDITY shorten filter life. |
DO NOT introduce large slugs of water into filter. |
BLOW all lines and parts clear prior to installation. |
DO NOT use where pressure surges are likely. |
DO NOT use in system without earth ground. |
REMOVE all protective seals and closures. |
NOT FOR use in aircraft. |
ALWAYS follow standard operating procedures (SOP) for producing breathing gases. |
MAXIMUM USEFUL LIFESPAN is six months. Shelf life is two years. |
Nuvair offers authentic parts and equipment manufactured by Lawrence Factor®. Beware of inexpensive aftermarket imitations labeled as "replacement," "OEM equivalent," "compatible," or "alternative," as they are not made by Lawrence Factor®, Inc. Some Lawrence Factor® products may have extended lead times. To confirm compatibility with your existing equipment or to ensure the product meets your needs, please contact the Nuvair Sales Team for ordering assistance by email or phone.