The low pressure SPX Hankison HF 20 series filter package includes three stage filtration for up to 60 SCFM (1699 L/min) flow at 100 psi (7 bar). Comes equipped with a #10 SAE inlet fitting, on/off ball valve, and a #10 SAE fitting for a diver's hose. It is recommended for the Quincy 325 and Champion R15 compressor pumps. When used properly this filter pack removes moisture, 99.9999+% of particles 0.01 micron or larger, and oil vapor down to <0.003 ppm/w. Various options, including an aluminum frame (SKU 6063.2-FR), are available with this package at an additional cost.
Nuvair stocks low pressure breathing air filtration packages (housings and filters) commonly used in commercial diving. Whether you are looking for individual filters or multi-stage filtration packages, Nuvair has your solution in stock. Order individual components online or contact us to put together a package for your specific needs. Systems have a maximum operating pressure of 200 psi (14 bar).
SKU | Description |
---|---|
6063.2-2DM | Filter package with two-diver manifold |
6063.2-FR | Filter package mounted to aluminum frame |
6063.2-HPF | Filter package with HP feed input and HP>LP reducing regulator on 1/2" outlet |
6063.2-LPF | Filter package with on/off ball valve input manifold with regulator on 1/2" outlet |
6063.2-LPF-BP | Filter package with back pressure regulator on 1/2" outlet |
If you are interested in purchasing an upgraded version of this Hankison filter pack, please contact the sales team for ordering assistance.
Drain Type | Maximum Operating Pressure | Maximum Operating Temperature | Minimum Operating Temperature |
---|---|---|---|
Drain Plug | 300 psi (21 bar) | 150°F (66°C) | 35°F (2°C) |
Internal Automatic Drain | 250 psi (17 bar) | 150°F (66°C) | 35°F (2°C) |
Drain plug standard. Externally mounted automatic drains are available.
ISO performance data of the three-stage HF Series filter housing when configured with Grade 1 (Oil Vapor Removal), Grade 5 (High Efficiency Oil Removal), and Grade 7 (Air Line) filter elements:
Element | Removes | ISO 8573.1: 2010 Air Quality Class | Where Used |
---|---|---|---|
Grade 7 | ∙ Solids 1.0 micron and larger ∙ Remaining oil content 1 ppm/w |
∙ Solid Particles: Class 2 ∙ Remaining Oil Content: Class 4 |
∙ Upstream of ultra high efficiency oil removal filters ∙ At point-of-use if aftercooler/separator installed upstream |
Grade 5 | ∙ 99.999+% of solids 0.01 micron and larger ∙ Remaining oil content <0.008 ppm/w |
∙ Solid Particles: Class 1 ∙ Remaining Oil Content: Class 1 |
∙ Upstream of desiccant dryers ∙ Downstream of refrigerated dryers ∙ At point-of-use if aftercooler/separator installed upstream |
Grade 1 | ∙ Removes 99.9999+% of solids 0.01 micron and larger ∙ Remaining oil content <0.003 ppm/w (as a vapor) |
∙ Solid Particles: Class 1 ∙ Remaining Oil Content: Class 1 |
∙ Downstream of high efficiency oil removal filters |
Nuvair is an Authorized Hankison® Distributor
Nuvair sells only genuine parts and equipment manufactured by SPX Flow Hankison®. Do not be fooled by cheap aftermarket copies of original Hankison equipment. Items labeled “replacement” or “alternative” are not manufactured by SPX Flow Hankison.
Some SPX Flow Hankison parts are not are not regularly stocked. To determine product availability and lead time, please contact the Nuvair sales team for ordering assistance.